Search results for "optical variables measurement"

showing 3 items of 3 documents

Review of space charge measurement systems: acoustic, thermal and optical methods

2016

In the last decade, remarkable developments have concerned the methods of space charge measurement in the field of insulation systems diagnostic. In particular, methods based on acoustic and thermal phenomena have been largely used. The present review provides a broad overview on the different techniques used describing, for each of them, the working principle, the main features and the most relevant applications. Further details are provided for the Pulsed Electro-Acoustic (PEA) method, as it seems to be the most used. This article provides more details on its historical evolution, showing evidence for its technological limits and taking into consideration the advantages and drawn from the…

010302 applied physicsEngineeringField (physics)business.industry020209 energySystem of measurementMechanical engineering02 engineering and technology01 natural sciencesSpace chargeSettore ING-IND/31 - ElettrotecnicaSpace charge Charge measurement Acoustics Optical variables measurement Electrodes Acoustic measurements Optical pulses0103 physical sciencesThermal0202 electrical engineering electronic engineering information engineeringElectrical and Electronic EngineeringbusinessThermal methodsIEEE Transactions on Dielectrics and Electrical Insulation
researchProduct

Influence of the electro-optical properties of an a-Si:H single layer on the performances of a pin solar cell

2012

We analyze the results of an extensive characterization study involving electrical and optical measurements carried out on hydrogenated amorphous silicon (α-Si:H) thin film materials fabricated under a wide range of deposition conditions. By adjusting the synthesis parameters, we evidenced how conductivity, activation energy, electrical transport and optical absorption of an α-Si:H layer can be modified and optimized. We analyzed the activation energy and the pre-exponential factor of the dark conductivity by varying the dopant-to-silane gas flow ratio. Optical measurements allowed to extract the absorption spectra and the optical bandgap. Additionally, we report on the temperature dependen…

Amorphous siliconThin film materialThin film solar cell Activation energySingle junctionConductivitySettore ING-INF/01 - ElettronicaSettore FIS/03 - Fisica Della Materialaw.inventionchemistry.chemical_compoundElectric conductivitylawMaterials ChemistryThin filmAbsorption (electromagnetic radiation)Preexponential factorGas-flow ratioMetals and AlloysSurfaces and InterfacesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsTemperature dependenceHydrogenated amorphous siliconOptoelectronicsElectric propertieQuantum efficiencyHydrogenationOptical data processingDeposition conditionSiliconMaterials scienceActivation energyQuantum efficiencySynthesis conditionVapor deposition SiliconOpticsSolar cellActivation energyDark conductivityCharacterization studieElectromagnetic wave absorptionThin filmDepositionElectrooptical propertieThin film solar cellConductivitybusiness.industryEnergy conversion efficiencySolar cellAmorphous siliconMeyer-Neldel ruleOptical propertieOptical measurementelectro-optical propertiesNanostructured materialSilicon; Solar cell; electro-optical propertiesElectrical transportchemistrySynthesis parameterOptical variables measurementSingle layerConversion efficiencybusinessOptical gap
researchProduct

Camera-based measurement of relative image contrast in projection displays

2013

International audience; This research investigated the measured contrast of projection displays based on pictures taken by un-calibrated digital cameras under typical viewing conditions. A high-end radiometer was employed as a reference to the physical response of projection luminance. Checkerboard, gray scale and color complex test images with a range of the projector's brightness and contrast settings were projected. Two local and two global contrast metrics were evaluated on the acquired pictures. We used contrast surface plots and Pearson correlation to investigate the measured contrast versus the projector's brightness and contrast settings. The results suggested, as expected, the proj…

[ INFO.INFO-TS ] Computer Science [cs]/Signal and Image Processingoptical projectors[INFO.INFO-TS] Computer Science [cs]/Signal and Image Processingprojection luminanceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processingmeasured contrastradiometersImage color analysismetrics[INFO.INFO-TS]Computer Science [cs]/Signal and Image Processingstatistical analysispicture acquisitioncamerasgray scaleBrightnessoptical variables measurementdigital cameracamera-based measurementRadiometry[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processingdisplay devicesDigital camerasuncalibrated digital cameraglobal contrast metricsprojector brightness settingscheckerboardcolor complex test imagesrelative image contrastviewing conditionsradiometerimage processingCorrelationPearson correlationhigh-end radiometerprojection displayprojector contrast settings[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingprojection displayscontrast surface plotsstatistic based metrics
researchProduct